Last updated Wed Sep 29 15:38:22 PDT 1999
| Component | Requirements 1 | 
|---|---|
| Motors:- | - | 
| Limits 2: Bimba reed switch #MRS-.087-XBL-02 | Two (2) per cylinder Four (4) total | 
| Fiducials:- | - | 
| Encoders:- | - | 
| Air Cylinders: Two (2) | Bimba #MRS-025-DXP-UG | 
| Air Solenoids: Two (2) | Honeywell #73419AN2NN00M1J011C2 24 Volt DC | 
| Lock/Clamp/Brake:- | - | 
| Interlocks:- | - | 
NOTES:
| Component | Maximum Operating Condition | Safe Ops Condition | Requirements | 
|---|---|---|---|
| Motors: | - | - | - | 
| Limits: | - | - | - | 
| Fiducials: | - | - | - | 
| Encoders: | - | - | - | 
| Air Cylinders: | - | - | 40 PSI | 
| Air Solenoids: | - | - | 40 PSI | 
| Lock/Clamp/Brake: | - | - | - | 
Mechanical Drawing(s) #
Electronic Drawing(s) # EL-1183
Sign conventions are such that a positive motion of the motor turns the motor in a CW direction as viewed from the drive shaft looking back into the motor, and will the drive the stage towards the forward limit.