Component | Requirements * |
---|---|
Motors: | - |
Gearbox: | - |
Limits **: Bimba reed switch #MRS-.087-XBL-02 | Two (2) per cylinder
Four (4) total |
Fiducials: | - |
Encoders: | - |
Air Cylinders: Two (2) | Bimba #MRS-025-DXP-UG |
Air Solenoids: Two (2) | Honeywell #73419AN2NN00M1J011C2
24 Volt DC |
Lock/Clamp/Brake: | - |
Interlocks: | - |
* Speed, temperature, accuracies, electrical power, pressurized
air, lubricant, coolant, N2 purge, ...
** Primary (inner) and secondary (outer) limits. These can
be magnetic, optical, or physical contact
NOTES:
Component | Maximum Operating Condition | Safe Ops Condition | Requirements |
---|---|---|---|
Motors: | - | - | - |
Gearbox: | - | - | - |
Limits: | - | - | - |
Fiducials: | - | - | - |
Encoders: | - | - | - |
Air Cylinders: | - | - | - |
Air Solenoids: | - | - | - |
Lock/Clamp/Brake: | - | - | - |
Mechanical Drawing(s) #
Electronic Drawing(s) # EL-1183-2S (shutter controller)
Sign conventions are such that a positive motion of the motor turns the motor in a CW direction as viewed from the drive shaft looking back into the motor, and will the drive the stage towards the forward limit.