Performance requirements and design goals | |
Component | Requirements 1 |
---|---|
Motors: Galil 50-1000 | 3750 RPM / 205 in-oz peak stall torque |
Limits 2: Microswitch BZ-2RW822-A2 "soft" + DT-2RV22-A7 "hard" | |
Fiducials: Opto-interupter TRW #OPB-970-T55 (Optical) | |
Encoders: Gurley 8335-11250-CB-S-A | |
Air Cylinders: None | |
Air Solenoids: None | |
Lock/Clamp/Brake: None | |
Interlocks: Lockout during manual installation of new grating (see lockout schedule) |
Manufacturer's specifications and limitations | |||
Component | Maximum Operating Condition | Safe Ops Condition | Requirements |
---|---|---|---|
Motors: | |||
Limits: | |||
Fiducials: | |||
Encoders: | |||
Air Cylinders: | |||
Air Solenoids: | |||
Lock/Clamp/Brake: |
Motor tuning parameters under different spacial orientations and environment | ||
Parameter | Set | |
---|---|---|
Motor Type: |
|
|
PID Filter: | KD: |
|
KP: |
|
|
KI: |
|
|
Acceleration (pulses/sec^2): |
|
|
Deceleration (pulses/sec^2): |
|
|
Speed: |
|
|
Set: CN 1,1 CB 1 CEA=2 |
|
Rotary Stage (constrained) | ||||
Distance from "home" | Position | Motor Counts | Gurley Counts | Time to Reach |
---|---|---|---|---|
Primary (inner) Limits: | Forward |
|
|
|
Reverse |
|
|
||
Secondary (outer) Limits: | Forward |
|
|
|
Reverse |
|
|
||
Position # None (any posn available) | 1 |
|
|
|
2 |
|
|
||
3 |
|
|
||
4 |
|
|
||
5 |
|
|
||
6 |
|
|
||
1 revolution | CW |
|
|
|
CCW |
|
|
||
Gurley Index Position |
|
|
Resolution of Stage | |||
Encoder | Counts/Inch | Counts/Millimeter | Counts/Degree |
---|---|---|---|
On Motor |
|
|
|
On Gurley |
|
Electronic Drawing(s) #EL-3058 and EL-3059
Sign conventions are such that a positive motion of the motor turns the motor in a CW direction as viewed from the drive shaft looking back into the motor, and will drive the stage towards the forward limit.
The Grating Tilt #1 stage uses Controller # 2, amplifier 2A and is connected to the A axis.