Component | Requirements 1 |
---|---|
Motors:Galil #50-1000 | |
Gearbox: None | |
Limits 2: Microswitch BZ-RW822-A2 "primary" and DT-2RV22-A7 "secondary" | |
Fiducials: TRW #OPB-970-T55 (Optical) | |
Encoders: Gurley #8335-11250-CB-S-A, 900,000 counts/rev (Labeled DEIMOS-2) | |
Air Cylinders:- None | |
Air Solenoids:- None | |
Lock/Clamp/Brake:- Yes |
|
Interlocks: See lockout schedule |
Component | Maximum Operating Condition | Safe Ops Condition | Requirements |
---|---|---|---|
Motors: | |||
Gearbox: | |||
Limits: | |||
Fiducials: Optical | |||
Encoders: | |||
Air Cylinders: | |||
Air Solenoids: | |||
Lock/Clamp/Brake: |
Parameter | Set | |
---|---|---|
PID Filter: | KD: |
|
KP: |
|
|
KI: |
|
|
Acceleration (pulses/sec^2): |
|
|
Deceleration (pulses/sec^2): |
|
|
Speed (pulses/sec): |
|
|
Set: CN 1,1 CB 3 CEC=8 |
Distance from "home" | Position |
|
|
Time to Reach |
---|---|---|---|---|
Software Limits: | Forward |
|
||
Reverse |
|
|||
Total Rotation | - |
|
|
|
Primary (inner) Limits: | Forward |
|
|
|
Reverse |
|
|
|
|
Secondary (outer) Limits: | Forward |
|
|
|
Reverse |
|
|
|
|
Defined Positions | 1 |
|
|
|
2 |
|
|
||
3 |
|
|
||
4 |
|
|
||
5 |
|
|
||
6 |
|
|
||
1 revolution | CW |
|
|
|
CCW |
|
|
||
Gurley Index Position |
|
|
Encoder | Counts/Inch | Counts/Millimeter | Counts/Degree |
---|---|---|---|
On Motor | - | - |
|
On Gurley | - | [1 Gurley count = 10.35 Motor Encoder counts.] |
|
Electronic Drawing(s) #EL-3064 and EL-3065
Sign conventions are such that a positive motion of the motor turns the motor in a CW direction as viewed from the drive shaft looking back into the motor, and will drive the stage towards the forward limit.
The Grating Tilt #4 stage uses Controller #2, amplifier 2A and is connected to the C axis.