Last updated:12-6-01
Project: DEIMOS
Stage:CCD Translation Stage
ID #: KDCX-001A
Engineer: D. Cowley (T. Freeman)
Mechanical Description of Stage:
UHV linear Drive driven by Galil motor through a Berg slip clutch. Estimated
travel +/- 1mm.
Electronic Description of Stage:
The CCD Translation stage is driven by Galil controller
#1, amplifier 1B and is connected to axis F.
Required setting accuracy :
Performance requirements and design goals
Component |
Requirements 1 |
Motors: Galil 5-500 |
|
Gearbox: UHV Linear Drive PN: VZLDS225M |
|
Limits 2: MicroSwitch 311SM6-T |
|
Fiducials: TRW #OPB 970-T55 (Optical) |
|
Encoders: 500 counts/rev |
|
Air Cylinders:- |
|
Air Solenoids:- |
|
Lock/Clamp/Brake:- |
|
Interlocks:- |
|
-
Speed, temperature, accuracies, electrical power, pressurized air,
lubricant, coolant, N2 purge, ...
-
Primary (inner) and secondary (outer) limits. These can be magnetic,
optical, or physical contact
Manufacturer's specifications and limitations
Component |
Maximum Operating Condition |
Safe Ops Condition |
Requirements |
Motors: |
5 oz-in continuous, 42 oz-in peak torque. Max. speed: 5400 RPM |
|
|
Gearbox: |
|
|
|
Limits: |
|
|
|
Fiducials: |
|
|
|
Encoders: |
Resolution: 500 counts/rev |
|
|
Air Cylinders: |
|
|
|
Air Solenoids: |
|
|
|
Lock/Clamp/Brake: |
|
|
|
Final Mechanical Assembly and Testing Results
Tests performed by:
Motor tuning parameters under different spacial
orientations and environment
Parameter |
|
Set to: |
PID Filter: |
KD: |
400
|
KP: |
80
|
KI: |
30
|
Acceleration (pulses/sec^2): |
|
256,000
|
Deceleration (pulses/sec^2): |
|
256,000
|
Speed (pulses/sec): |
|
20
|
Other: CN 1,-1 CB 10 |
|
|
-
Uphill defined as motor (or driven end of shaft) in lowest position
Motion Parameters
Linear Stage (constrained)
Distance from "home" 1
|
Position
|
Motor Counts
|
Physical Units
|
Time to Reach
|
Software Limits: |
Forward
|
800
|
TBD
|
Limit to Limit:
|
Reverse
|
-2260
|
TBD
|
= 34 Seconds
|
Primary (inner) Limits: |
Forward
|
+ 945
|
-0.030"
|
|
Reverse
|
- 2507
|
0.0295"
|
|
Secondary (outer) Limits: |
Forward
|
+ 1289
|
-0.0355"
|
|
Reverse
|
- 2730
|
0.0335"
|
|
Fiducial: |
-
|
0
|
-0.014"
|
|
-
"Coarse" if from optical interupter, "Fine" if from an encoder index
pulse. Home is defined as zero counts.
-
Primary limits signal the controller to stop motion. Secondary limits
cut motor power and require intervention to move out of them.
-
Positive (+) motor drive moves the stage to the right (looking from
the front of the dewar).
Resolution of Stage
Encoder |
Counts / Mil. |
On Motor |
57 counts /0 .001"
|
-
Backlash:
-
Forward: - 300 counts at speed
-
Reverse: +300 counts at speed
-
Repeatability:
-
Fiducial:
-
Encoder:
-
Air Cylinders:
-
Air Solenoids:
NOTES:
Mechanical Drawing(s) Stage: D7356-1
Electronic Drawing(s) EL-3055
Sign conventions are such that a positive motion of the motor turns
the motor in a CW direction as viewed from the drive shaft looking back
into the motor, and will drive the stage towards the forward limit.