Last updated: 12-6-01
Project: DEIMOS
Stage: CCD Focus
ID #: KDCF-001A
Engineer: D. Cowley (T. Freeman)
Mechanical Description of Stage:
Belt Drive with 5:1 ratio driven by Galil motor through a Berg slip clutch.
Estimated travel +/- 1mm.
Electronic Description of Stage:
Driven by Galil Controller #1 - Amplifier 1B - Stage
"E"
This stages requires an EL-1236R (Reverse) interface
box.
Required setting accuracy :
Performance requirements and design goals
Component |
Requirements 1 |
Motors: Pitman 9234C645-R1 30.3 VDC |
|
Gearbox: Direct Belt Drive with ratio of 1:5 |
|
Limits 2: MicroSwitch 311SM6-T |
|
Fiducials: TRW #OPB 970-T55 (Optical) |
|
Encoders: 2000 counts / rev |
|
Air Cylinders:- |
|
Air Solenoids:- |
|
Lock/Clamp/Brake:- |
|
Interlocks:- |
|
-
Speed, temperature, accuracies, electrical power, pressurized air,
lubricant, coolant, N2 purge, ...
-
Primary (inner) and secondary (outer) limits. These can be magnetic,
optical, or physical contact
Manufacturer's specifications and limitations
Component |
Maximum Operating Condition |
Safe Ops Condition |
Requirements |
Motors: |
5 oz-in continuous, 42 oz-in peak torque. Max. speed: 5400 RPM |
|
|
Gearbox: |
|
|
|
Limits: |
Micro switch |
|
|
Fiducials: |
Optical TRW OPB970T55 |
|
|
Encoders: |
Resolution: 2000 counts/rev |
|
|
Air Cylinders: |
|
|
|
Air Solenoids: |
|
|
|
Lock/Clamp/Brake: |
|
|
|
Final Mechanical Assembly and Testing Results
Tests performed by: K. Dietsch
Motor tuning parameters under different spacial
orientations and environment
Parameter |
|
Set to: |
PID Filter: |
KD: |
154
|
KP: |
29
|
KI: |
27
|
Acceleration (pulses/sec^2): |
|
256,000
|
Deceleration (pulses/sec^2): |
|
256,000
|
Speed (pulses/sec): |
|
500
|
Set the following parameters: CN 1,-1
CB 9 |
|
|
Motion Parameters
Linear Stage (constrained)
Distance from "home" 1 |
Position |
Motor Counts |
Physical Units |
Time to Reach |
Software Limits: |
Forward
|
268
|
|
Limit to Limit
|
Reverse
|
-19400
|
|
= 47 Seconds
|
Primary (inner) Limits: |
Forward
|
536
|
-0.037"
|
10 Seconds
|
Reverse
|
-20550
|
0.042"
|
38 Seconds
|
Secondary (outer) Limits: |
Forward
|
1356
|
-0.041"
|
|
Reverse
|
-22079
|
0.046"
|
|
Fiducial: (Driving in + dir.) |
|
0
|
-0.035"
|
Time "0"
|
-
"Coarse" if from optical interupter, "Fine" if from an encoder index
pulse. Home is defined as zero counts.
-
Primary limits signal the controller to stop motion. Secondary limits
cut motor power and require intervention to move out of them.
-
Positive (+) motor drive moves focus stage toward the front of the
dewar.
Resolution of Stage
Encoder |
Counts/mil. |
On Motor |
267.22 counts / 0.001"
|
-
Backlash:
-
Repeatability:
-
Fiducial:
-
Encoder:
NOTES:
Mechanical Drawing(s) #Stage #D7356-1
Electronic Drawing(s) # EL-3054, EL-1236R2
Sign conventions are such that a positive motion of the motor turns
the motor in a CW direction as viewed from the drive shaft looking back
into the motor, and will drive the stage to the forward limit (toward the
window).